Scope
This specification covers the requirements for the design, fabrication, and use of our pre-insulated low-temperature pipe supports. These supports are for pipes having surface temperature ranges of &#;460 ˚F (-273 ˚C ) to 280 ˚F (138 ˚C ).

General Requirements
&#; Cryogenic pipe supports shall comply with the following standards:
A. ANSI/ASME B31.1 & B31.3
B. Manufacturers Standardization Society SP-58, 69, & 89.
&#; The following criteria shall be considered in the selection of low-temperature pre-insulated pipe supports:
A. Vertical, lateral and axial support design load limits.
B. Vertical, lateral, and axial support design travel limits.
C. The temperature of the cryogenic pipe support, at the pipe surface, and ambient conditions.
D. All test or pre-operational loads that may exceed normal operating conditions.
E. Any dimensional clearances needed during installation and operation should be specified.
F. Material for any items that will be welded directly to the pipe.
G. All loading and displacements caused by seismic, hydraulic surge, or other disturbances.
H. The temperature at the support steel.
&#; Upon request by the purchaser or the end user, design calculations of supports will be made available for review.
&#; Upon request by the purchaser or the end user, localized stress calculations for lugs and other welded attachments will be made available for review.
&#; Prior to placing an order, all special requirements such as mill test reports, material certification or non-standard materials must be specified.

Design Criteria
&#; The load bearing insulating materials used in the pre-insulated pipe support shall be the same material that was used to rate the support.
&#; At the request of the end user or the purchaser, we will make available compressive strength and thermal conductivity testing results of the high-density polyurethane in the format provided by MSS SP-89. Testing will be done at the maximum temperature of -196oC .
&#; A description of the quantity of load that can be applied to the support shall be provided for evaluation upon request. A minimum safety factor of 5 at the system design temperature shall be used to determine the maximum load.
&#; Testing for compressive strength properties shall comply with ASTM D, the standard testing method, for compressive properties of Rigid Cellular Plastics.
&#; Testing for thermal conductivity shall comply with ASTM C177, Steady-State Heat Flux Measurements, and Thermal Transmission Properties, by means of the Guarded Hot Plate Apparatus.
&#; Load bearing element capacity shall be demonstrated at the system design temperature and load.
&#; The pre-insulated pipe support assembly shall exert enough clamping force to assure that the support will move axially with the pipe and will not slip when under design conditions.
&#; All slide plate surfaces shall be designed so that the coefficient of friction will be limited to .1 for the design life without requiring lubrication. Any friction reducing material that requires bonding shall be bonded to a backing structure prior to shipment.
&#; High-density polyurethane shall have the following maximum thermal conductivity:
A. 10 lb./cu.in. foam &#; .114 BTU-in/hr-ft2 &#; oF (. W/m- o K)
B. 14 lb./cu.in. foam &#; .12 BTU-in/hr-ft2 &#; oF (. W/m- o K)
C. 20 lb./cu.in. foam &#; .22 BTU-in/hr-ft2 &#; oF (. W/m- o K)
&#; CFC&#;s shall not be used in the manufacture of high-density polyurethane foam.

Goto Zhiang to know more.

Additional reading:
Metal Stamping Techniques to Maximize Cost Savings
How Does Fiberglass Mesh For Sale Work?

Fabrication
&#; All polyurethane foam shall be monolithic and molded oversized so that excess material shall be removed by cutting to achieve the final finished dimensions, the outer skin shall be removed.
&#; The pre-insulated pipe support shall:
A. Come pre-assembled with sufficient insulation extending past the outer metal jacket, allowing the pipe insulator to butt the line insulation against it.
B. All exposed surfaces will be coated with mastic to protect the foam from moisture and UV degradation. The mastic will have a minimum perm rating of .02 (ASTM E-96).
C. The vapor barrier between the metallic jacket and the insulating material will also have a perm rating of .02.
D. The ID and OD dimensions of the insulation shall conform to ASTM specification C585 unless otherwise specified.
&#; Designs having sliding surfaces shall incorporate two slide plates at each surface. Each slide plate will be made of 3/32&#; thick glass filled reinforced PTFE, 25% glass filled, bonded to a 10GA carbon steel backing plate. The PTFE, 25% glass filled, will be recessed ¼&#; from the edge of the plate.
&#; All welding shall comply with B31.3 and B31.1 Piping Code and AWS D1.1
&#; The following items unless otherwise noted on contract drawings shall be in accordance with the following:
A. Structure shapes and plate: ASTM A-36
B. Bolts and studs: ASTM A-307
C. Nuts: A563

Cryogenic Supports with Permali® Block

The above design shows cryogenic supports with Permali® block. Permali® block is a laminated phenolic material from layers of wood impregnated under vacuum and heat with synthetic resin. These pipe shoes can be designed to restrain very high axial, lateral and vertical loads. These shoes are used for LNG pipeline sliding supports with TEF slide plates.

Do you require cryogenic pipe supports for a current or future project? Get pricing today!





For more cryogenic pipe supports manufacturerinformation, please contact us. We will provide professional answers.

Comments

0

0/2000

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name:(required)

Your Email:(required)

Subject:

Your Message:(required)

0/2000