The document discusses construction solutions from VSL including bar systems for reinforcing, post-tensioning, geotechnical applications, and more. VSL has been manufacturing and designing bar systems since 1971 for uses like inducing and controlling loads and forces in structures. Their bar systems are available in various grades for different applications and include features like threaded bars that can be cut or extended as needed. VSL also provides value-added services around their bar systems.
Contact us to discuss your requirements of thread bar for geotechnical price. Our experienced sales team can help you identify the options that best suit your needs.
150 KSI All-Thread-Bar
150 KSI-All-Thread Bar
Nominal BarDiameter
& Pitch Minimum
Net Area
Thru Threads Minimum
Ultimate
Strength Prestressing Force Nominal
Weight Approx.
Thread
Major Dia. Part
Number 0.80f pu A 0.70f pu A 0.60f pu A 1” – 4
(26 mm) 0.85 in2
(549 mm2) 128 kips
(567 kN) 102 kips
(454 kN) 89.3 kips
(397 kN) 76.5 kips
(340 kN) 3.09 lbs/ft
(4.6 kg/m) 1-1/8”
(29 mm) R71-08 1-1/4” – 4
(32 mm) 1.25 in2
(807 mm2) 188 kips
(834 kN) 150 kips
(667 kN) 131 kips
(584 kN) 113 kips
(500 kN) 4.51 lbs/ft
(6.7 kg/m) 1-7/16”
(37 mm) R71-10 1-3/8” – 4
(36 mm) 1.58 in2
(1019 mm2) 237 kips
(1054 kN) 190 kips
(843 kN) 166 kips
(738 kN) 142 kips
(633 kN) 5.71 lbs/ft
(8.5 kg/m) 1-9/16”
(40 mm) R71-11 1-3/4” – 3-1/2
(46 mm) 2.60 in2
(1664 mm2) 390 kips
(1734 kN) 312 kips
(1388 kN) 273 kips
(1214 kN) 234 kips
(1041 kN) 9.06 lbs/ft
(13.5 kg/m) 2”
(51 mm) R71-14 2-1/4” – 3-1/2
(57 mm) * 4.08 in2
(2632 mm2) 613 kips
(2727 kN) 490 kips
(2181 kN) 429 kips
(1909 kN) 368 kips
(1636 kN) 14.1 lbs/ft
(20.8 kg/m) 2-1/2”
(64 mm) R71-18 2-1/2” – 3
(65 mm) 5.19 in2
(3350 mm2) 778 kips
(3457 kN) 622 kips
(2766 kN) 545 kips
(2422 kN) 467 kips
(2074 kN) 18.2 lbs/ft
(27.1 kg/m) 2-3/4”
(70 mm) R71-20 3” – 3
(75 mm) 6.85 in2
(4419 mm2) 1027 kips
(4568 kN) 822 kips
(3656 kN) 719 kips
(3198 kN) 616 kips
(2740 kN) 24.1 lbs/ft
(35.8 kg/m) 3-1/8”
(80 mm) R71-24
- The 2-1/4” diameter bar is not covered under ASTM A722.
ACI 318-14, Section 17.5.1.2 indicates that the nominal shear strength of an anchor not exceed 0.60 x area of steel x the ultimate stress of the steel.
- Per PTI recommendations for anchoring, anchors should be designed so that:
- The design load is not more than 60% of the specified minimum tensile strength of the prestressing steel.
- The lock-off load should not exceed 70%of the specified minimum tensile strength of the prestressing steel.
- The maximum test load should not exceed 80% of the specified minimum tensile strength of the prestressing steel.
- Maximum test load and maximum factored design load must not exceed the yield strength of ANY steel element.
Structural Properties
YieldStress Ultimate
Stress Elongation in
20 bar diameters Reduction
of Area 120 KSI
(827 MPa) 150 KSI
(1034 MPa) 4% 20% min.
Sizes
Williams 150 KSI bars are manufactured in 7 diameters from 1” (26 mm) through 3” (75 mm). All diameters are available in continuous lengths up to 50’ (15.2 m)
Steel Quality
Williams 1” through 1-3/8” 150 KSI bars are smooth, hot rolled, high strength prestressing steel. The bars are cold-stressed and stress relieved in strict compliance with ASTM A722 and AASHTO M275 Highway Specifications. The 1-3/4” through 3” 150 KSI bars are made from alloy steel that is hot rolled, quenched and tempered to meet to the prescribed mechanical properties of ASTM A722. Thorough inspection and traceability are carried out during all phases of manufacturing to assure the highest standards of quality.
Properties
Williams 150 KSI bars are high in strength yet ductile enough to exceed the specified elongation and reduction of area requirements. Selected heats can also pass the 135° supplemental bend test when required. Testing has shown Williams 150 KSI All-Thread-Bars to meet or exceed post tensioning bar and rock anchoring criteria as set by the Post Tensioning Institute including dynamic test requirements beyond 500,000 cycles of loading. Williams 360° continuous thread deformation pattern has the ideal relative rib area configuration to provide excellent bond strength capability to grout or concrete, far better than traditional reinforcing deformation patterns.
Threads
All-Thread-Bars are cold rolled threaded to close tolerances under continuous monitoring procedures for quality control. Threads for Williams 150 KSI bar are specially designed with a rugged thread pitch wide enough to be fast under job site conditions and easy to assemble. They also have a smooth, wide, concentric, surface suitable for torque tensioning. This combination offers tremendous installation savings over inefficient, hot rolled, non-concentric thread forms. Threads are available in both right and left hand. Williams All-Thread-Bars are threaded around the full circumference enabling the load transfer from the bar to the fasteners to occur efficiently without eccentric point loading. Williams fasteners easily meet the allowable load transfer limitations set forth by the Post TensioningInstitute. Williams 150 KSI All-Thread-Bars and fasteners are machined to tight tolerances for superior performance and mechanical lock. Precision machining greatly reduces concern of fastener loosening or detensioning. Williams 150 KSI bars exceed the deformation requirements of ASTM A722. Williams special thread deformation pattern projects ultra-high relative rib area, much greater than conventional rebar. This provides for superior bond performance in concrete.
Tensile Strength & Working Loads
Williams 150 KSI bars are available with ultimate tensile strengths and working loads as displayed above. Safety factors and functional working loads are at the discretion of the project design engineer, however, test loads should never exceed 80% of the published ultimate bar strength.
Cutting (No Welding)
Williams 150 KSI All-Thread-Bar should not be subjected to the heat of a torch, welding or used as a ground. Field cutting should be done with an abrasive wheel or band saw.
150 KSI All-Thread-Bar Accessories
All Couplings and Hex/Collar Nuts exceed 100% of the bar’s published ultimate strength and couplings will meet ACI 318 Section 25.5.7.1 for mechanical rebar connections.
R72 Stop-Type Couplings
BarDiameter Outside
Diameter Overall
Length Part
Number 1”
(26 mm) 1-3/4”
(44 mm) 4”
(102 mm) R72-08 1-1/4”
(32 mm) 2-1/8”
(54 mm) 4-1/2”
(114 mm) R72-10 1-3/8”
(36 mm) 2-3/8”
(60 mm) 5”
(127 mm) R72-11 1-3/4”
(46 mm) 3”
(76 mm) 8-1/2”
(216 mm) R72-14 2-1/4”
(57 mm) 3-1/2”
(89 mm) 8-1/2”
(216 mm) R72-18 2-1/2”
(65 mm) 4-1/4”
(108 mm) 8-5/8”
(219 mm) R72-20 3”
(75 mm) 5”
(127 mm) 11-7/8”
(302 mm) R72-24
R73 Hex Nuts / R74 Collar Nuts
Hex Nut Rounded Collar Nut
For more 20mm threaded rebar factoryinformation, please contact us. We will provide professional answers.
BarDiameter Across
Flats Across
Corners Thickness Part
Number 1”
(26 mm) 1-3/4”
(44 mm) 2.0”
(51 mm) 1-5/8”
(41 mm) R73-08 1-1/4”
(32 mm) 2-1/4”
(57 mm) 2.6”
(66 mm) 1-7/8”
(48 mm) R73-10 1-3/8”
(36 mm) 2-1/2”
(64 mm) 2.9”
(73 mm) 2-1/8”
(54 mm) R73-11 1-3/4”
(46 mm) 3”
(76 mm) 3.5”
(88 mm) 3-1/2”
(89 mm) R73-14 2-1/4”
(57 mm) 3-3/4”
(95 mm) 4.3”
(109 mm) 3-3/4”
(95 mm) R73-18 2-1/2”
(65 mm) 4-1/4”
(108 mm) 4.9”
(124 mm) 3-3/4”
(95 mm) R73-20 3” *
(75 mm) 4-1/2”
(114 mm) OD 5”
(127 mm) 5-1/2”
(140 mm) R74-24
* Rounded Collar Nut
R88 Spherical Hex Huts
Provides up to 5 ̊ angle when used with a dished plate
BarDiameter Across
Flats Thickness Outside
Dome Part
Number 1”
(26 mm) 1-3/4”
(44 mm) 2-1/4”
(57 mm) 2-1/2”
(64 mm) R88-08 1-1/4”
(32 mm) 2-1/4”
(57 mm) 2-3/4”
(70 mm) 3-1/8”
(80 mm) R88-10 1-3/8”
(36 mm) 2-1/2”
(64 mm) 3-1/4”
(83 mm) 3-5/8”
(90 mm) R88-11 1-3/4”
(46 mm) 3”
(76 mm) 3-1/2”
(89 mm) 4”
(102 mm) R88-14 2-1/4” *
(57 mm) 3-3/4”
(95 mm) 5-1/4”
(133 mm) 5-1/2”
(140 mm) R73-18
R81-18 2-1/2” *
(65 mm) 4-1/4”
(108 mm) 5-1/2”
(140 mm) 6”
(152 mm) R73-20
R81-20 3” **
(75 mm) 4-1/4”
(108 mm) 7-1/2”
(191 mm) 7”
(178 mm) R74-24
R81-24
R73/R74-JN Jam Nuts
Hex Jam Nut Rounded Collar Jam Nut
Jam Nuts can not be substituted for full strength nuts. Larger diameters will be a rounded collar jam nut, with special order machined hex available.
BarDiameter Across
Flats OD/Across
Corners Thickness Part
Number 1”
(26 mm) 1-3/4”
(44 mm) 2”
(51 mm) 0.41”
(10 mm) R73-08JN 1-1/4” *
(32 mm) 1-7/8”
(48 mm) OD 2-1/8”
(54 mm) 0.47”
(12 mm) R73-10JN 1-3/8” *
(36 mm) 2-1/8”
(54 mm) OD 2-3/8”
(60 mm) 0.53”
(14 mm) R73-11JN 1-3/4” *
(46 mm) 2-3/4”
(70 mm) OD 3”
(76 mm) 0.88”
(22 mm) R73-14JN 2-1/4”*
(57 mm) 3-1/4”
(83 mm) OD 3-1/2”
(89 mm) 0.94”
(24 mm) R73-18JN 2-1/2” *
(65 mm) 4”
(102 mm) OD 4-1/4”
(108 mm) 0.94”
(24 mm) R73-20JN 3” *
(75 mm) 4-1/2”
(114 mm) OD 5”
(127 mm) 1.38”
(35 mm) R74-24JN
*Round Collar Jam Nut
R9F Hardened Washers
BarDiameter Outside
Diameter Inside
Diameter Thickness Part
Number 1”
(26 mm) 2-1/4”
(57 mm) 1-3/16”
(30 mm) 5/32”
(4 mm) R9F-09-436 1-1/4”
(32 mm) 2-3/4”
(70 mm) 1-1/2”
(38 mm) 5/32”
(4 mm) R9F-11-436 1-3/8”
(36 mm) 3”
(76.2 mm) 1-5/8”
(41 mm) 5/32”
(4 mm) R9F-12-436 1-3/4”
(46 mm) 3-3/4”
(95 mm) 2-1/8”
(54 mm) 7/32”
(6 mm) R9F-16-436 2-1/4”
(57 mm) 4-1/2”
(114 mm) 2-5/8”
(67 mm) 9/32”
(7 mm) R9F-20-436 2-1/2”
(65 mm) 5”
(127 mm) 2-7/8”
(73 mm) 9/32”
(7 mm) R9F-22-436 3”
(75 mm) 6”
(152 mm) 3-3/8”
(86 mm) 9/32”
(7 mm) R9F-26-436
To achieve full strength of the system, hardened washers must be used with R73 hex nuts
R8M Beveled Washers
BarDiameter Degree
of Bevel Outside
Diameter Inside
Diameter Maximum
Thickness Minimum
Thickness Part
Number 1”
(26 mm) 10° 2-27/32”
(72 mm) 1-7/16”
(37 mm) 7/8”
(22 mm) 3/8”
(10 mm) R8M-08-150 1-1/4” *
(32 mm) 15° 3-3/8”
(86 mm) 1-9/16”
(40 mm) 1-15/64”
(44 mm) 3/8”
(10 mm) R8M-12S 1-3/8”
(36 mm) 15° 3-1/2”
(89 mm) 1-3/4”
(44 mm) 1-1/4”
(32 mm) 3/8”
(10 mm) R8M-13S 1-3/4”
(46 mm) 15° 5-1/4”
(133 mm) 2-1/4”
(57 mm) 1-5/8”
(41 mm) 5/16”
(8 mm) R8M-16-150 2-1/4”
(57 mm) 10° 6-1/2”
(165 mm) 3”
(76 mm) 1-7/8”
(48 mm) 3/4”
(19 mm) R8M-18-150 2-1/2”
(65 mm) 10° 7-1/2”
(190 mm) 3-1/2”
(89 mm) 2.31”
(59 mm) 1”
(25 mm) R8M-20-150 3”
(75 mm) 10° 8”
(203 mm) 3-5/8”
(92 mm) 2.43”
(62 mm) 1”
(25 mm) R8M-24-150
To achieve full strength of the system, beveled washers must be used in conjunction with a hardened washer.
If you are looking for more details, kindly visit hot rolled thread bar manufacturers.
If you are interested in sending in a Guest Blogger Submission,welcome to write for us!